IT equipment safety (IEC 60950-1)

LCS TESTING LAB

IT equipment safety (IEC 60950-1)

Scope, test items, common findings and certification routes.

IEC 60950-1 — safety of information technology equipment

IEC 60950-1 is the safety standard for information technology equipment, covering mains-connected IT equipment and its accessories. Note that IEC 60950-1 has been superseded by IEC 62368-1 in most markets; a 60950-1 report is still useful for legacy products, for markets that have not migrated, and as the basis for a 62368-1 gap upgrade. We test to 60950-1 and can carry the same sample over to a 62368-1 evaluation.

Products covered

Information technology equipment and its power supplies, including equipment powered from the mains or from a remote supply.

Power adaptersRouters & switchesSet-top boxesDesktop & server PSUsMonitorsPrintersPoE equipmentTelecom terminal equipment

Main test items

  • Marking, instructions and language requirements
  • Input current, power and rating verification
  • Temperature rise at normal load and at the declared maximum load
  • Electric strength (hipot), insulation resistance and insulation coordination
  • Touch current / leakage current measurement
  • Clearance, creepage distance and insulation distances on PCB and transformer
  • Fire enclosure, flammability of materials and openings
  • Mechanical strength, impact, stability and wall-mount strength
  • Moisture treatment followed by electric strength
  • Abnormal operation and single-fault conditions (component short / open)
  • Capacitor discharge, earth continuity and protective bonding
  • Construction of transformers, optocouplers and other critical components

Common reasons a sample is rejected

Finding Why it fails
Clearance / creepage short on the primary sideSlot routing and conformal coating are often counted as spacing when they do not qualify.
Transformer construction not to the required insulation categoryMargin tape width, triple insulation and winding order must match the declared insulation class.
Temperature rise above the limitSmall adapters running at full load, and output capacitors placed against the case.
Fire enclosure openings too large or material too flammableVent holes and bottom openings are measured against the fire-enclosure rules, not visual judgement.
Touch current above the limitY-capacitor selection and the discharge resistor network are the usual cause.
Single-fault test leads to smoke or flameProtective devices and component ratings were not checked under short / open conditions.
Critical components without valid certificationX/Y capacitors, varistors, fuses and optocouplers must carry acceptable component approvals.
Marking or instructions incompleteModel, input rating, caution marks and language set must match the target market.

Certification routes

  • CB Scheme — IECEE certificate and report on IEC 60950-1 (with -21 / -22 where telecom or telecom wiring applies)
  • CE — Low Voltage Directive 2014/35/EU; for new designs the harmonised route is now EN IEC 62368-1
  • North America and China — new listings generally require the 62368-1 equivalent (UL/CSA 62368-1, GB 4943.1); 60950-1 reports are kept for legacy models and existing certifications

Sample and timing

Samples: 2 to 3 production units, plus the critical component list with their approvals, transformer drawings and PCB layout. Lead time is confirmed after the output configuration and the target market are fixed; if the market has migrated to 62368-1, we quote the gap assessment in the same run.

LCS TESTING LAB · Electrical & lighting

Inquiry / Request a quote

Tell us what you need, we reply within 24 hours.

LCS

One-stop testing and certification for ESS and lithium batteries — UN38.3, IEC 62619, CE, UL, FCC and more.

Contact

+86 177 2252 2312
© 2026 LCS Testing Group. All rights reserved.