IEC 62311:2019 (second edition) cancels and replaces the 2007 first edition, with BS EN IEC 62311:2020 as the European adoption. It is the fallback assessment basis for equipment without a dedicated EMF product standard, and older reports are increasingly asked to be updated during channel reviews.
What happened
IEC 62311 is a generic standard from TC 106 covering 0 Hz to 300 GHz that assesses whether electronic and electrical equipment complies with human exposure limits. It provides methods and criteria only; the limits come from the applicable regional regulation. The 2019 edition is a technical revision that cancels and replaces the 2007 edition.
What changed
- A clear distinction between intentional radiators (radio transmitters) and unintentional radiators (motors, transformers)
- Treatment of exposure to non-uniform fields is introduced
- Uncertainty handling in the assessment procedures is improved
- Assessment methods can be used for both general public and occupational exposure
- The standard does not specify basic restrictions or reference levels; those remain in regional regulations
Impact on exporters
| Stage | Impact |
|---|---|
| Report validity | 2007-edition reports are more likely to be sent back for reissue in EU channel reviews |
| Storage and charging equipment | Power-frequency field assessment for PCS, inverters and chargers is now clearer |
| Wireless charging | Near-field and non-uniform field requirements rise, so calculation methods must be updated |
| Multi-transmitter products | Superposition becomes routine; single-source compliance is no longer enough |
Recommended actions
- Review which reports are on the 2007 edition and reissue high-risk categories to 2019
- Check separation distances and power-frequency assessment for storage and charging products
- Add simultaneous-transmission assessment for multi-radio products
- Record the limit source and regulation revision in the technical file
Sources
Need to update an older 62311 report?
Send the report and product list; we assess whether retesting is needed under the 2019 edition and reuse existing data wherever possible.
WhatsApp / 微信:+86 177 2252 2312