Lithium battery IEC/EN 62133 safety testing
IEC 62133-2 / EN 62133-2 / cells and packs
Lithium battery IEC/EN 62133 safety testing
IEC 62133-2 is the common safety standard for rechargeable lithium cells and the basis for most national conversions: the EU assesses to EN 62133-2, while Korea, Japan, India, Taiwan and Australia usually convert from a CB certificate. Testing runs at two levels — cells for design margin and packs for protection-circuit behaviour under abuse. For international schemes projects it is normally scheduled alongside UN38.3 and whole-unit safety (62368-1) so samples are not shipped twice.
Regulations and standards
| Regulation / directive / standard | Standards | Scope |
|---|---|---|
| IEC 62133-2:2017 + AMD1:2021 | Safety of rechargeable lithium cells and packs | Clauses judged separately for cells (7.2 / 7.3) and packs (7.3) |
| EN 62133-2 | EU harmonised standard | Pairs with CE-LVD; the report supports the DoC technical file |
| Cell clauses | Overcharge, forced discharge, external short circuit, crush, drop, thermal abuse, low pressure | Sample counts scale with cell size and energy |
| Pack clauses | Overcharge protection, external short circuit, drop, thermal cycling, vibration | Includes protection-circuit failure and single-fault conditions |
| Relation to other standards | IEC 62619 / UL 2054 / GB 31241 | 62133 does not replace the destination's national differences |
Main test items
Each item below is run against the standard listed above with raw data recorded on site; the report gives measured values and a pass/fail verdict per item, and one re-test after corrective action is included.
Samples and documents
- 10 cells and 8 packs including protection boards
- Cell datasheet, BOM and protection-board parameters
- Unit manual and rating label
- Existing CB certificate or report when converting
Lead time and deliverables
10–15 working days for the report; cell and pack testing can run in parallel, and difference-only testing takes 5–7 working days.
IEC/EN 62133-2 test report, critical-component and protection-parameter checklist, and a national-difference note for conversion.
Inquiry / Request a quote
Tell us what you need, we reply within 24 hours.
17722522312
Same number as our phone. Search it in WeChat to add us, or call 17722522312

One-stop testing and certification for ESS and lithium batteries — UN38.3, IEC 62619, CE, UL, FCC and more.
Contact
+86 177 2252 2312- sunny.lcs@powcert.com
- Juji Industrial Park, Shajing, Bao'an District, Shenzhen, China